What was found
LOWER END OF 947 STUB FRAME AT 21R INTERCOSTAL HAS AREAS OF CORROSION. ACFT GROUNDED. CORROSION FOUND OUT OF LIMITS, R & R INTERCOSTAL IAW SRM 51-40-02-0G-0, W 3, O .032, R .025, L 5, D .007.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LOWER END OF 947 STUB FRAME AT 21R INTERCOSTAL HAS AREAS OF CORROSION. ACFT GROUNDED. CORROSION FOUND OUT OF LIMITS, R & R INTERCOSTAL IAW SRM 51-40-02-0G-0, W 3, O .032, R .025, L 5, D .007.