What was found
FLOOR ANGLE AT BS 500G IS EXFOLIATED STR 25L TO STR 25R. ACFT GROUNDED. REMOVED DAMAGED ANGLE , FABRICATED NEW ANGLE AND INSTALLED IAW SRM 51-40-02-0G-0, SRM 51-40-05-0G-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR ANGLE AT BS 500G IS EXFOLIATED STR 25L TO STR 25R. ACFT GROUNDED. REMOVED DAMAGED ANGLE , FABRICATED NEW ANGLE AND INSTALLED IAW SRM 51-40-02-0G-0, SRM 51-40-05-0G-0.