What was found
RIGHT FMC FAIL. ACFT GROUNDED. PERFORMED RT FMC BITE 34-61, TASK 801. FOUND RT FMC FAIL FAULTS. DUE TO PREVIOUS, REPLACED NR 2 FMC COMPUTER, REMOVED AND INSTALLED RT FMC COMPUTER, REF 34-61-02. ACCOMPLISHED SW LOAD IAW 34-61-00/201. SET PERFORMANCE FACTOR ADJUSTMENT TASK 34-61-00. PERFORMED FMC, OPS TEST TASK 34-61-00, SYS CKS NORMAL.