What was found
MAIN CABIN FLOOR SUPPORT ANGLE CRACKED & BROKEN BS 540, LBL 1. ACFT GROUNDED. REMOVED CABIN FLOOR SUPPOERT ANGLE AT BS S40 AND INSTALLED LBL1 IAW SEM 51-40-02, LOCATED, DRILLED AND INSTALLED NEW FLOOR SUPPORT ANGLE, PN 143AS5240-35 IAW SRM 51-40-02 AND BAC DWG 143A5240, REV- REMOVED DOT R052, PO 847234.3.