What was found
FRAME AT BS 992 HAS AREAS OF CORRODED JUST ABOVE L2 MOPSILL. ACFT GROUNDED. REPAIRED FRAME IAW EA 400 53EA, 15969. THIS IS A CAT B REPAIR WITH TRACKING IAW 400, 53DTI, 15970. INSPECTION THRESHOLD OF 66,000 FLT CYCLES, CURRENT FLT CYCLES AT TIME OF REPAIR IS 30,578, W 1", O .071", R .051", L 5", D .020".