As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD PIT RT TRANSITION PANEL AT BS 440 AND S-25RH IS CORRODED. ACFT GROUNDED. REMOVED DAMAGED SHIELD IAW SRM 51-40-02. RECEIVED NEW FWD SHIELD, PN 143A8126U21, PO 851805.17. AND LOCATED AND DRILLED FASTENER HOLES IAW SRM 51-40-05. INSTALLED NEW FWD SHIELD AND NUTPLATES AS REQUIRED IAW SRM 51-40-02.