What was found
AFT PIT, FLOORBOARD SUPPORT CORRODED. BS 887, LBL 16 - RBL 16. ACFT GROUNDED. R & R CORRODED FLOOR SUPPORT AT BS 887, LBL16-RBL16, PN 14A9401U39, PO: 852826.3 IAW SRM 51-40-02 AND DWG 146A7500, REV "A" DOT REMOVED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT PIT, FLOORBOARD SUPPORT CORRODED. BS 887, LBL 16 - RBL 16. ACFT GROUNDED. R & R CORRODED FLOOR SUPPORT AT BS 887, LBL16-RBL16, PN 14A9401U39, PO: 852826.3 IAW SRM 51-40-02 AND DWG 146A7500, REV "A" DOT REMOVED.