What was found
UPON RECALL, GOT MASTER CAUTION LIGHT RT PACK ILLUMINATED. CAUTION LIGHT GOES OUT UPON RESETTING MASTER CAUTION. ACFT GROUNDED. PERFORMED PACK TEMP CONT BITE REF FIM 21-62, TASK 801, RT PACK LOGGED TCV FAULT LAST FLT PERFORMED, FIM 21-62, TASK 831 & FAULT CLEARED GROUND VERIFICATION CK GOOD.