Service difficulty report · Control Valve · Boeing 737890

Difficulty date
November 5, 2015
Submitted
November 9, 2015
Operation
Air carrier
Aircraft
N557AS
Make and model
Boeing 737890
Aircraft serial
35176
Aircraft time
36,217 hours, 10,722 cycles
Part
Control Valve
Part number
3989083
Part serial
8682
Condition
Failed
Location
Rt A/C Pack
Part time
36,249 hours, 10,734 cycles
Stage of operation
NR
How discovered
O
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found