What was found
FWD PIT TIE DOWN FITTING AT BS 500C RT GOUGED. ACFT GROUNDED. BLENDED GOUGE IAW SRM 53-00-53-1A-2 MAX ALLOWABLE .270" LOST .036" REMAINING .234" FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2, DETAIL G, SEC D-D AND BAC DWG NR 143A7501, REV: REMOVED DAMAGE SECTION FROM BS 500B+10 - 500C+10 IAW SRM 53-00-53-1A-2, REPAIR 3. FABRICATED NEW TRACK SECTION AND 2 EA TRACK SPLICE IAW SRM 53-00-53-2R-3, REPAIR 3. ALODINED AND PRIMED IAW SRM 51-20-01. INSTALLED NEW REPAIR TRACK SECTION AND 2 EA TRACK SPLICE IAW SRM 53-00-53-2R-3 REPAIR 3. REMOVED DOT.