What was found
RIGHT TRANSTION PANEL CORRODED FROM BS 727A-767, MAINLY AROUND SCREW HOLES AND EDGES. ACFT GROUNDED. REMOVED CORROSION FROM BS 727A-727F IAW SRM 53-00-53. ORIGINAL MATERIAL THICKNESS .040 MATERIAL LOST .003 AND REMAINING .037 FOUND TO BE WITHIN LIMITS IAW SRM 53-00-53. ALODINED, PRIMED AREAS IAW SRM 51-20-01, HASH MARKED AREAS IAW AMM 51-05-01. REMOVED CORROSION FROM BS 727F-BS 767 IAW SRM 53-00-53. ORIGINAL THICK .040 REMOVED .006, REMAINING .034, FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53. REMOVED RT TRANSITION PANEL FROM BS 727F+10-BS 767, FABRICATED NEW ZEE CHANNEL AND SPLICE SIDEPLATE IAW SRM 53-00-53-2R-5. ALODINED AND PRIMED IAW SRM 51-24-01 AND INSTALLED IAW SRM 53-00-53-2R-5, REPAIR 5. REMOVED DOT: A437.