What was found
AFT CARGO COMPARTMENT FLOOR, LEFT TRANSITION PANEL UPPER SKIN SEVERAL SPOTS CORROSION BS 727+8-BS 727E, STR 25L-STR 26L. ACFT GROUNDED. REMOVED CORROSION BS 727+8 TO 727C+8 IAW SRM 53-00-53-1A-2, ORIGINAL MATERIAL THICKNESS IS 0.040" REMAINING THICKNESS IS 0.037", REMOVED 0.003". ALODINED REWORKED AREAS IAW SRM 51-20-01, PRIMED REWORKED AREAS IAW SOPM 20-41-02. MARKED BLENDOUT AREAS IAW AMM 51-05-01. REMOVED CORROSION BS 727C+9 TO 727E & FOUND BEYOND ALLOWABLE LIMITS IAW IAW SRM 53-00-53-1A-2. ORIGINAL MATERIAL THICKNESS IS 0.040", REMAINING THICKNESS IS 0.033", REMOVED 0.007". ACCOMPLISHED SPLICE REPAIR APPROXIMATELY BS 727C+9 TO 727E IAW SRM 53-00-53-2R-5. REMOVED DOT .