What was found
AFT CARGO COMPARTMENT FLOOR, RT TRANSITION PANEL UPPER SKIN SEVERAL SPOTS, CORROSION & DRILL MARKS BS 727F+9 -BS 727I+9, STR 25R-STR 26R. ACFT GROUNDED. REMOVED CORROSION BS 727F+9 TO BS 727I+9 ORIGINAL THICKNESS IS .040. TOTAL MATERIAL REMOVED IS .003, REMAINING THICKNESS IS .037". EXCLUDING BS 727H+20, AREA FOUND TO BE WITHIN LIMITS IAW SRM 53-00-53-1A-2, FIG 103. ALODINED & PRIMED & MARKED BLENDOUT AREAS, IAW SRM 51-20-01 & AMM 51-05-01 BS 727H+20. ORIGINAL THICKNESS .040 TOTAL MATERIAL REMOVED .016 REMAINING THICKNESS .024 AREA FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2F. ACCOMPLISHED SPLICE REPAIR A+ BS 727H+20 IAW SRM 53-00-53-2R-5. DOT REMOVED .