What was found
FWD CARGO COMPARTMENT, FRAME SHEAR TIE IS CORRODED AT BS 500I, BETWEEN S-26R AND S-27R. ACFT GROUNDED. REMOVED CORROSION AND FOUND BEYOND ALLOWABLE LIMITS IAW SRM 53-00-01-1A-5. ORIGINAL MATERIAL THICKNESS IS 0.050 IN, REMAINING THICKNESS IS 0.040", REMOVED 0.010" R & R SHEAR TIE IAW SRM 51-10-02, PARA 9, 51-40-02, AND DWGS 143A1234, REV A, AND 143A3230, REV B.