What was found
UPON SHUTTING DOWN ENGINES, BOTH SPAR VALVES CLOSED LIGHTS REMAIN ON BRIGHT BLUE. ACFT GROUNDED. PERFORMED FIM TASK 28-22, TASK 809 AND FIM TASK 28-22, TASK 810 WITH NORMAL FUNCTION ON BOTH SPAR VALVES. NO BRIGHT BLUE LIGHTS ILLUMINATED AFTER TEST, OPS CHECK GOOD.