What was found
BS 986 FLOORBEAM UPPER HORIZONTAL FLANGE HAS NUMEROUS AREAS OF CORROSION. ACFT GROUNDED. BLENDED CORROSION ON 986 FLOORBEAM UPPER CHORD, OUT OF LIMITS, REPAIRED UPPER CHORD IAW EA 400 53EA 16236, SRM 53-60-51-1A-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 986 FLOORBEAM UPPER HORIZONTAL FLANGE HAS NUMEROUS AREAS OF CORROSION. ACFT GROUNDED. BLENDED CORROSION ON 986 FLOORBEAM UPPER CHORD, OUT OF LIMITS, REPAIRED UPPER CHORD IAW EA 400 53EA 16236, SRM 53-60-51-1A-1.