What was found
FWD CARGO COMPARTMENT, AFT BULKHEAD TO FLOOR LOWER SUPPORT ANGLE HAS CORROSION INTERGRANULAR. ACFT GROUNDED. REMOVED CORROSION IAW SRM 53-00-53, ORIGINAL MATERIAL 0.071, MATERIAL LOSS .0.019 FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53. REMAINING MATERIAL 0.052, UT GAGE, T8225U. REMOVED SUPPORT ANGLE IAW SRM 57-40-02. INSTALLED POSITIONED DRILLED AND DEBURRED IAW SRM 57-40-05 AND 51-40-02, NEW ANGLE PO 853691.3.