What was found
WHILE ACCOMPLISHING TASK CARD 78273000, FOUND ECONOMIC FAULT 77-20861 BOTTOM LT EGT SIGNAL IS OUT OF RANGE NR 1 ENGINE. ACFT GROUNDED. CLEANED EGT HARNESS AND INSPECTED IAW FIM 77-21, TASK 803 BOTTOM LT EGT SIGNAL IS OUT OF RANGE-FAULT ISOLATION. ELECTRONIC ENGINE CONTROL TEST, PASSED. T49.5 SECTOR INDICATIONS PRE-CLEANING: 1-129.00, 2-90.87, 3-95.62, 4-137.62. POST CLEANING: 1-40.37, 2-21.37, 3-25.75, 4-40.62. NO FAULTS.