What was found
AFT PIT LT TRANSITION PANEL FROM BS 727 TO BS 787 HAS CORROSION NUMEROUS SPOTS. ACFT GROUNDED. REMOVED CORROSION ON AFT PIT LT TRANSITION PANEL IAW SRM 51-10-02. FROM BS 727- BS 747 ORIGINAL THICKNESS IS .040, REMOVED .010, REMAINING THICKNESS IS .030 OUT OF LIMITS. R & R DAMAGED SECTION IAW SRM 53-00-53-2R-5 FROM BS 747 -BS 787 ORIGINAL THICKNESS IS .040, REMOVED .002, REMAINING .038 FOUND TO BE IN LIMITS IAW SRM 53-00-53. ALODINED & PRIMED IAW SRM 51-20-01 & TOPCOAT IAW AMM 51-21-74, APPLIED CIC IAW SOPM 20-41-02.