What was found
AFT CARGO LT TRANSITION PANEL FROM BS 727 TO 787 HAS CORROSION NUMEROUS SPOTS. ACFT GROUNDED. REMOVED CORROSION ON AFT PIT LT TRANSITION PANEL IAW SRM 51-10-02. FROM BS 727- BS 747 ORIGINAL THICKNESS IS .040, REMOVED .010, REMAINING THICKNESS IS .030 OUT OF LIMITS. R & R DAMAGED SECTION IAW SRM 53-00-53-2R-5 FROM BS 747-BS 787, ORIGINAL THICKNESS IS .040, REMOVED .002, REMAINING .038 FOUND TO BE IN LIMITS IAW SRM 53-00-53. ALODINED & PRIMED IAW SRM 51-20-01 & TOPCOAT IAW AMM 51-21-74 APPLIED CIC IAW SOPM 20-41-02.