What was found
RIGHT PACK LIGHT ILLUMINATED ON TAXI OUT. IAW PILOT DEBRIEF, WITH THROTTLES ADVANCED, RT PACK TEMP INDICATOR INCREASED WITH THROTTLES. TEMP IN 60 DEGREE C RANGE. RT PACK LIGHT WOULD NOT RESET. ACFT GROUNDED. BITE OF PACK ZONE TEMP CONTROLLERS, NO FAULTS LOGGED. NO HISTORY LAST 60 DAYS. ACCOMPLISHED HEALTH CHECK ON RT ENGINE, TC NG-36WC-00001, NO DEFETS NOTED. ACCOMPLISHED A LEAK CHECK OF RT PACK FCSV, NO DEFECTS. REF FIM TASK 21-53, TASK 802, STEP F 5. ACCOMPLISHED ENGINE BLEED AIR CROSSOVER TEST AND RAN PACKS. NO DEFECTS NOTED, REF MM TASK 26-11-00-710-801.