What was found
RT PACK CAUTION LIGHT ILLUMINATED DURING CRUISE. 32,000 AND 40 PSI DUCT PRESSURE, RT PACK CAUTION DID NOT EXTINGUISH AFTER SYSTEM RESET. ACFT GROUNDED. PERFORMED FIM TASK 21-62, TASK 854, STEP E. MAINTENANCE MESSAGE SHOWN FOR RAM AIR EXIT. EXAMINED RAM AIR EXIT ACTUATORS, 28 VOLTS DC BETWEEN PINS 4 & 16, GREEN N2 LRU FAULT ON. PERFORMED REPAIR CONFIRMATION PER STEP 6 AND NO FAULTS NOTED. PERFORMED AMM TASK 21-51-00-730-801 AND NO FAULTS NOTED. PACK OPERATES NORMALLY WITH NO FAULTS NOTED.