What was found
FWD WET AREA FLOOR SUPPORT, BS 312 TO BS 328, RBL 12 IS CORRODED. ACFT GROUNDED. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-10-51-A-1 DETA 0. R & R THE FLOOR SUPPORT IAW SRM 51-40-02-0G-0 AT BS 312 TO BS 328, RBL 12, W 1.0, O .080, R .034, L 2.09, D .046.