Service difficulty report · Actuator · Boeing 737990ER

Difficulty date
January 20, 2016
Submitted
January 25, 2016
Operation
Air carrier
Aircraft
N464AS
Make and model
Boeing 737990ER
Aircraft serial
40714
Aircraft time
6,771 hours, 2,168 cycles
Part
Actuator
Part number
676000141
Part serial
676000141898
Condition
Malfunctioned
Location
Ram Air
Part time
6,799 hours, 2,177 cycles
Stage of operation
NR
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

LEFT PACK LIGHT ILLUMINATED ON RECALL. RESET WITH MASTER CAUTION. ACFT GROUNDED. TECH SERVICE REQUEST, R & R THE LT TEMP CONTROL VALVE IAW AMM 21-51-10-000/400-801. BITE CHECK GOOD IAW AMM 21-61-00-700-806. LEAK CHECK GOOD. ON FIRST BITE CHECK, FOUND SRADA INLET FAULT. SUSPECT LT RAM AIR INLET ACTUATOR HAS INTERMITTENT FAULT. REPLACED THE LT RAM AIR INLET ACTUATOR REF AMM 21-51-21-000-801 AND 21-51-21-400-801. INLET DOOR ACTUATOR TEST PASS. BITE CHECK PASS REF AMM 21-51-21-400-801.