What was found
UPON REMOVAL OF L2 DOOR SILL WEB BS 986-992 FOUND CRACKED STR TIE AT STR 19L, BS 986. ACFT GROUNDED. R & R STRINGER CLIP IAW SRM 51-40-02-0G-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
UPON REMOVAL OF L2 DOOR SILL WEB BS 986-992 FOUND CRACKED STR TIE AT STR 19L, BS 986. ACFT GROUNDED. R & R STRINGER CLIP IAW SRM 51-40-02-0G-0.