What was found
REF TSR 817439, FOUND NR 2 FUEL QTY TANK UNIT CAPACITANCE OUT OF TOLERANCE. ACFT GROUNDED. ACCOMPLISHED SYS TEST OF NR 2 FUEL QTY INDICATING SYS IAW AMM 28-41-00-730-801. FOUND NR 2 TANK TOTAL CAPACITANCE AT 414 PICOFARADS AND OUT OF LIMITS. ACCOMPLISHED TANK AND COMPENSATOR UNITS TEST IAW AMM 28-41-21-710-801, REF TABLE 504, FOUND TANK UNIT 9 READING OUT OF LIMITS AT 43.06 PICOFARADS WITH A RANGE OF 32.55-34.05. FOUND TANK UNIT 10 READING OUT OF LIMITS AT 49.71 WITH A RANGE OF 27.11-28.61. R & R TANK UNITS 9 AND 10 IAW AMM 28-41-21. RECHECKED TANK TOTAL CAPACITANCE AND FOUND TO BE WITHIN LIMITS AT 398.1. ACCOMPLISHED FQIS COMPARISON CHECK IAW AMM 28-41-00-720-801. NO DIFFERENCE FROM STICK AND INDICATED QTY. LEAK CHECK OK, REF AMM 28-11-00-400-801.