What was found
TEMP PROBE LIGHT ILLUMINATED DURING PUSHBACK. ACFT GROUNDED. ACCOMPLISHED FIM TASK 30-31-810 UP TO STEP E. TEMP PROBE LIGHT CAME ON & STAYED ON. R & R TAT PROBE IAW AMM 34-21-06-400-801, OPS CHECKED GOOD. INSTALLED BP MFG PN 102AH2AG FROM UNITED. SEALANT NOT APPLIED IAW STEP 3, LINE K. INSPECTED BP, IN GOOD CONDITION.