What was found
FWD CARGO COMPARTMENT RT TRANSITION PANEL HAS SEVERAL AREAS OF CORROSION FROM BS 500B TO BS 500I. ACFT GROUNDED. REMOVED CORROSION FROM BS 500B-500D IAW SRM 53-00-53. ORIGINAL MATERIAL THICKNESS .040, MATERIAL REMOVED .002, AND REMAING .038, FOUND TO BE WITHIN LIMITS IAW SRM 53-00-53 ALODINED AND PRIMED IAW SRM 51-20-01 AND HAS MARKED IAW AMM 51-05-01. REMOVED CORROSION FROM BS 500D-500I IAW SRM 53-00-53, FOUND TO BE OUT OF LIMITS. REMOVED TRANSITION PANEL FROM BS 500B+10-STA 500 IAW SRM 53-0053 AND FABRICATED ZEE CHANNEL SIDEPLATE AND SPLICE SIDEPLATE IAW SRM 53-00-53-2R-5, REPAIR 5 ALODINED AND PRIMED IAW SRM 51-20-01 AND INSTALLED IAW SRM 53-00-53-2R-5, REPAIR 5.