Service difficulty report · Control Valve · Boeing 737890

Difficulty date
February 20, 2016
Submitted
February 24, 2016
Operation
Air carrier
Aircraft
N558AS
Make and model
Boeing 737890
Aircraft serial
35177
Aircraft time
37,052 hours, 10,856 cycles
Part
Control Valve
Condition
Malfunctioned
Location
A/C Pack
Stage of operation
NR
How discovered
9
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

PACK LIGHT ILLUMINATED ON MASTER CAUTION RECALL. EXTINGUISHES ON MASTER CAUTION RESET. ACFT GROUNDED. ZONE TEMP CONTROLLER BITE TEST FAULTED THE LT PACK TEMP CONTROL VALVE AND WOULD NOT RESET. R & R THE LT PACK TCV IAW AMM 21-51-21. ZONE TEMP CONTROLLER BITE TEST PASSED WITH NO FAULTS. ALSO, THE HEAT EXCHANGERS WERE CLEANED, REF T/C 78121000.