What was found
WHILE ACCOMPLISHING TASK CARD 78273000, ENGINE 2 LOGGED ECONOMIC FAULT 73-31372, UPPER EGT SENSORS READING HIGH. ACFT GROUNDED. ACCOMPLISHED FAULT ISOLATION IAW FIM 73-11, TASK 801. RAN ENGINE NR 2 AT IDLE FOR 5 MIN, ALL T49.5 PARAMETERS WERE IN RANGE, DID NOT FLUCTUATE. ELECTRONIC ENGINE CONTROL TEST PASSED. FAULT IS NOT ACTIVE AT THIS TIME.