What was found
AFT CARGO FLOOR SUPPORT AT RT BS 747+6 TO 847, RBL 12 CORRODED IN SEVERAL SPOTS. ACFT GROUNDED. CHECKED LIMITS IAW SRM 51-10-02 ORIGINAL MATERIAL .070", MATERIAL REMAINING AFTER BLENDOUT .059" FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53, FIG 103 TOOL T8225.5. REMOVED SCUFF PLATE IAW SRM 51-40-02, REMOVED FLOOR SUPPORT IAW SRM 51-40-02, FABRICATION ACCOMPLISHED ON NR 42676 AND CUSTOMER CARD G656676, INSTALLED FLOOR SUPPORT IAW SRM 51-40-02 AND INSTALL SCUFF PLATE IAW SRM 51-40-02 DOT REMOVED.