What was found
L2 DOOR SURROUND LOWER AUXILIARY SILL WEB IS CORRODED AT APPROXIMATELY BS 990, AT GROUND BLOCK LOCATION. ACFT GROUNDED. REMOVED CORROSION AND FOUND BEYOND ALLOWABLE LIMITS IAW SRM 53-70-15-1A-1, ORIGINAL MATERIAL THICKNESS IS 0.040", REMOVED 0.006 ", REMAINING THICKNESS IS 0.034". REMOVED DAMAGE WEB IAW SRM 51-40-02. FABRICATED NEW WEB IAW BAC DWG 147A8801, REV, INSTALLED NEW WEB IAW SRM 51-40-02 AND DWG 147A8801 REV AND SRM 51-10-02, PARA 9.