What was found
IN CLIMB, DISCOVERED APU RUNNING WITH APU START SWITCH OFF. CYCLED APU SWITCH TO ON THEN OFF. APU SHUTDOWN NORMALLY. STARTED APU IN FLIGHT, NORMAL START GOOD. ACFT GROUNDED. RESET POWER FOR ACFT. VERIFIED APU SWITCH CONTACTS ARE SECURED. VERIFIED SWITCH POSITION THRU INPUT MONITORING. SUCCESSFUL APU STARTS AND SHUTDOWNS REF AMM 49-61-00, 49-11-00. APU SHOWS NO CURRENT FAULTS.