986 FLOORBEAM UPPER FLANGE HAS AREAS OF CORROSION. ACFT GROUNDED. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-60-51-1A-1, REPAIRED BS 986.5, FLOOR BEAM UPPER CHORD IAW EA 400-53EA-16904W.