What was found
AFT CARGO COMPARTMENT FRAME AT BS 847 FAIL SAFE ANGLE CORRODED STR 24R TO 25R. ACFT GROUNDED. BLENDED CORROSION ON FAIL SAFE FOUND TO BE OUT OF LIMITS REMOVED FABRICATED NEW, LOCATED, DRILLED, APPLIED ALODINE, PRIME, TOPCOATED, INSTALLED AND APPLIED CIC TO AFFECTED AREA IAW SRM 53-00-07-1A-1, FIG 1, SRM 51-4-02-0G-0, SRM 51-40-05-0G-0 FIG 2, SRM 51-20-01-0G-0. W 1, O .045, R .022, L 3.0, D .023.