What was found
AFT CARGO COMPARTMENT, RT FLOOR SUPPORT ZEE CHANNEL SECTION IS CORRODED, APPROXIMATELY BS 727J+6 TO BS 767. ACFT GROUNDED. REMOVED CORROSION AND FOUND BEYOND ALLOWABLE LIMITS IAW SRM 53-00-53-1A-2. ORIGINAL MATERIAL THICKNESS IS 0.040 IN, REMAINING THICKNESS IS 0.033", REMOVED 0.007". REPLACED DAMAGED SECTION APPROXIMATELY BS 727J+6, BS 767 RTH IAW SRM 53-00-53-2R-5 AND DWG 146A7500, REV A.