What was found
AFT CARGO COMPARTMENT, LT FLOOR SUPPORT ZEE CHANNEL SECTION IS CORRODED, APPROXIMATELY BS 727F+10 TO BS 727I+8. ACFT GROUNDED. REMOVED CORROSION AND FOUND BEYOND ALLOWABLE LIMITS IAW SRM 53-00-53-1A-2. ORIGINAL MATERIAL THICKNESS IS 0.040, REMAINING THICKNESS IS 0.034", REMOVED 0.006". REPLACED LT ZEE CHANNEL SECTION APPROXIMATELY BS 727F+10 TO 727I+8 IAW SRM 53-00-53-2R-5 AND BAC DWG 146A7500, REV A.