What was found
FWD CARGO COMPARTMENT, LT FLOOR SUPPORT CHANNEL SECTION APPROXIMATELY BS 500H+10 TO 500L IS CORRODED. ACFT GROUNDED. REMOVED CORROSION AND FOUND BEYOND ALLOWABLE LIMITS IAW SRM 53-00-53-1A-2, ORIGINAL MATERIAL THICKNESS IS 0.040", MINIMUM REMAINING THICKNESS IS 0.035", REPLACEMENT OF ZEE CHANNEL SECTION APPROXIMATELY BS 500H+10 TO 500L ACCOMPLISHED ON CARD G66452, IAW SRM 53-00-53-2R-5.