What was found
FWD CARGO COMPARTMENT, LT FLOOR SUPPORT ZEE CHANNEL SECTION APPROXIMATELY BS 500C+15 TO 500H+10 IS CORRODED. ACFT GROUNDED. REMOVED CORROSION APPROXIMATELY BS 500C+15 TO 500F+7 AND FOUND WITHIN ALLOWABLE LIMITS IAW SRM 53-00-53-1A-2, ORIGINAL MATERIALS THICKNESS IS 0.040 IN REMOVED 0.004", REMAINING THICKNESS IS 0.036" ALODINED REWORKED AREAS BS 500C+15 TO 500F+7 IAW SRM 51-20-01, PRIMED REWORKED AREAS BS 500C+15 TO 500F+7 IAW BS SOPM 20-41-02 APPLIED TOPCOAT AND BLENDOUT MARKING TO REWORKED AREAS BS 500C+15 TO 500F+7 IAW AMM 51-21-73 AND 51-05-01. REPLACED LT ZEE CHANNEL SECTION SA 500F+8 TO 500L IAW SRM 53-00-53-2R-5.