What was found
FRAME AT BS 344 HAS A CRACK INDICATION AT BS 4 RT LOWER FWD HOLE AT SPLICE. ACFT GROUNDED. REPAIRED DAMAGE TO FRAME IAW EA 400-53EA-17039. THIS REPAIR HAS A REINSPECT THRESHOLD OF 8,000 FLT. CYCLES AFTER MODIFICATION WITH A REPAIR INTERVAL OF 8,000 FLT. CYCLES. PERFORM THE INSPECTIONS SPECIFIED BY UJ-2 AT THE LAST 4 FASTENERS COMMON TO THE PD37-53-2526-1, REPAIR ANGLE AND THE FRAME WEB, LOCATE APPROXIMATELY AT BS 5.5R, FIG 4. ADDITIONALLY, PERFORM THE INSPECTION SPECIFIED BY UJ-2 AT THE LAST 2 FASTENERS COMMON TO THE PD37-53-2526-1. REPAIR ANGLE AND THE FRAME FLANGE LOCATED APPROXIMATELY AT STR 5.5R, FIG 4 OF EA 400-53EA-17039.