As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD PIT LT TRANSITION PANEL AT BS 500H-500I CORRODED. ACFT GROUNDED. REMOVED CORROSION FROM FWD PIT LT TRANSITION PANEL AT BS 500H-500I. ORIGINAL THICKNESS IS 0.040 IAW SRM 53-30-53. REMAINING MATERIAL 0.034. LOST MATERIAL 0.006, THE PANEL WAS OUT OF LIMITS IAW SRM 53-00-53. UT T8225Q. REMOVED DAMAGED SECTION AND REPLACED WITH NEW IAW SRM 53-00-53-2R-5. DOT REMOVED.