What was found
AFT CARGO COMPARTMENT, LEFT FLOOR SUPPORT ZEE CHANNEL SECTION APPROXIMATELY BS 727B+10-727D IS CORRODED. ACFT GROUNDED. REMOVED CORROSION FROM AFT PIT CARGO COMPARTMENT LT FLOOR SUPPORT 2EE CHANNEL FROM 727C+11 TO 727D ORIGINAL THICKNESS IS 0.04 TOTAL MATERIAL REMOVED ONLY 0.002 REMAINING MATERIAL 0.038 THE PANEL IS WITHIN LIMITS IAW SRM 53-00-53-1A-2. REMOVED CORROSION FROM BS 727B+10 TO 727C+10 ORIGINAL THICKNESS IS 0.040, REMOVED MATERIAL IS 0.006, REMAINING MATERIAL IS 0.034. THE AREA FOUND OUT OF LIMITS IAW SRM 53-00-53-1A-2. REMOVED DAMAGED SECTION AND FAB NEW REPAIR PARTS IAW SRM 53-00-53-2R-5. ALODINE & PRIMED IAW SRM 51-20-01. THEN INSTALLED IAW SRM 53-00-53-2R-5. LLT T8225V. ALODINED, PRIMED AND MARKED BLENDOUT AREAS BS 727C+11 TO 727D IAW SRM 51-20-01, SOPM 20-41-02 AND AMM 51-05-01.