What was found
AFT CARGO COMPARTMENT, LT FLOOR SUPPORT ZEE CHANNEL SECTION APPROXIMATELY BS 727K+10 TO 762 IS CORRODED. ACFT GROUNDED. REMOVED CORROSION AND FOUND BEYOND ALLOWABLE LIMITS IAW SRM 53-00-53-1A-2, ORIGINAL MATERIAL THICKNESS IS 0.040", REMAINING THICKNESS IS 0.032", REMOVED 0.008 IN ZEE CHANNEL SECTION BS 727K TO 807, REPLACED ON CARD G678335.