What was found
AFT CARGO COMPARTMENT, LOWER MAIN SILL WEB IS CORRODED. ACFT GROUNDED. REMOVED CORROSION FROM AFT CARGO LOWR SILL WEB ORIGINAL THICKNESS .045" IAW DWG 146A8123, REV F. MATERIAL LOSS .005", REMAINING THICK .040" FOUND TO BE OUT OF LIMITS IAW SRM 53-60-15-1A-1 FIG 103. TOOL T8225V. R & R WEB IAW SRM 51-10-02, PARA 9, 51-40-02, AND BAC 146A8340, REV B.