What was found
SAD DEFECT 55118362, DENT ON FUSELAGE EXTERNAL SKIN 1" ABOVE S-22R, BS310. REQUIRES RE-EVALUATION DUE TO NEW SRM REVISION REGARDING ALLOWABLE DENT LIMITS. ACFT GROUNDED. CUTOUT DAMAGE, FABBED AND INST REPAIR IAW SRM 53-00-01-2R-1. THIS REPAIR IS CAT B AND REQUIRES REPEAT INSP WITH A THRESHOLD OF 50,000 FLT CYCLES IAW SRM 53-00-01-2R-1, TABLE 205. ON RE-EVALUATION OF DENT FOUND TO BE OUT OF LIMIT IAW NEW CRITERIA OF SRM 53-00-01.