FOLLOW-UP TO RECENT HISTORY WITH NR 2 ENGINE FIRE WARNING LOOP A TEST FAIL. ACFT GROUNDED. R & R NR 2 CORE FIRE LOOP HARNESS MW0325, REF AMM 26-11-02. OPS CHECK OK.