FWD PIT LT TRANSITION PANEL CORRODED AT BS 500I TO 500C. ACFT GROUNDED. REMOVED CORROSION AND FOUND WITHIN ALLOWABLE LIMITS BS 500C TO 500H IAW SRM 53-00-53-1A-2, ORIGINAL MATERIAL THICKNESS IS .040 IN, REMOVED .002 IN THICKNESS REMAINING IS .038 IN. REFINISHED AND MARKED REWORKED AREA IAW SRM 51-20-01, SOPM 20-41-02, AND AMM 51-05-01. REMOVED CORROSION AND FOUND BEYOND ALLOWABLE LIMITS BS 500H TO 500I IAW SRM 53-00-53-1A-2, ORIGINAL MATERIAL THICKNESSS IS .040, REMOVED .009 IN THICKNESS REMAINING IS .031 IN REPLACED LT TRANSITION ZEE CHANNEL SECTION APPROXIMATELY BS 500G-15 TO 500I IAW SRM 53-00-53-2R-5.