What was found
AFTER T/O FUEL TOTALIZER READ 1000 HIGH, STARTED WITH 25.85 LBS, RAMP FUEL AT 10K QTY INDICATED 24.8 LBS, WITH 1.9 USED = 26.7 LBS, AT TOP OF CLIMB QTY INDICATED 21.6 WITH 4.45 LBS USED = 26.0 LBS. ALSO TOTALIZER FUEL READ 500 TO 600 GREATER THAN FMC FUEL USUALLY 100 TO 200 HIGH AFTER T/O. ACFT GROUNDED. ACARS FOB DID NOT RECORD ANY ABNORMAL FUEL TOTAL. ACCOMPLISHED FQIS OPERATIONAL TEST IAW AMM 28-41-00 & FMC OPERATIONAL TEST IAW AMM 34-61-00. NO HISTORY.