What was found
NR 1 ENGINE HAS SHORT TIME FAULT MESSAGE 73-10341. THE FMC POSITION SIGNAL IS OUT OF RANGE. ACFT GROUNDED. PERFORMED T/C 78273000, NO CURRENT FAULTS. PERFORMED NR 1 EEC TEST AND ACTUATOR TEST IAW FIM 75-34 TASK 807, NO FAULTS FOUND.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 1 ENGINE HAS SHORT TIME FAULT MESSAGE 73-10341. THE FMC POSITION SIGNAL IS OUT OF RANGE. ACFT GROUNDED. PERFORMED T/C 78273000, NO CURRENT FAULTS. PERFORMED NR 1 EEC TEST AND ACTUATOR TEST IAW FIM 75-34 TASK 807, NO FAULTS FOUND.