What was found
RIGHT PACK LIGHT DOES NOT EXTINGUISH ON MC RESET. ACFT GROUNDED. NR 1 TEMP CONTROLLER BITE TEST SHOWS TEMP CONTROLLER FAULT, & STANDBY PACK ON BITE TEST. PREVIOUS FLIGHT & VERIFY - PASS. RESET FAULT. FAULT DID NOT RETURN. BITE TEST NR 1 TEMP CONTROLLER GOOD. IAW AMM 21-51-00. FUNCTIONAL CHECK OF RIGHT PACK GOOD. PACK TEMP ADJUSTS.